Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Dent ; 144: 104918, 2024 May.
Article in English | MEDLINE | ID: mdl-38461887

ABSTRACT

OBJECTIVE: To determine the effect of airborne particle abrasion (APA) on micro-tensile bond strength (µTBS) to dentin using different air-abrasion/polishing powders. METHODS: The bonding effectiveness of G2 Bond Universal (G2B), used in etch-and-rinse (E&R) and self-etch mode (SE), was tested on bur-cut dentin and dentin air abraded/polished using six different powders (aluminum oxide 29 µm (AO29) and 53 µm (AO53), aluminum trihydroxide (AT), sodium bicarbonate (SB), sodium bicarbonate soft (SBsoft) and bioactive glass (BG); Velopex). Adhesive-composite resin specimens were immersed in distilled water at 37 °C for one week and cut into microspecimens. Half of the specimens were subjected to 50,000 thermocycles (aged). Immediate and aged µTBS to dentin were measured. Statistical analysis was performed using linear mixed-effects (LME) modeling (p < 0.05). RESULTS: Comparing the aged bond strengths to air-abraded/polished dentin with bur-cut dentin, pretreatment with SB and SBsoft in combination with G2B used in E&R mode, and BG air polishing in combination with both application modes (E&R, SE), resulted in a significantly higher bond strength. Dentin bond strength was only significantly lower when air abraded with AO29 and using G2B in SE mode. Aging did not significantly influence bond strength for both application modes (E&R, SE), except for AO29 and AT-treated dentin, where bond strengths decrea sed significantly using G2B in SE mode. In general, G2B reached significantly higher bond strengths on air-abraded/polished dentin in E&R mode than in SE mode. CONCLUSION: Air-abrasion/polishing did not impair dentin bond strength using G2B, except when dentin was air abraded with AO29 and using G2B in SE mode. Air polishing positively influenced the bond strength to dentin in specific groups. CLINICAL SIGNIFICANCE: APA is safe concerning bonding to dentin. The E&R application mode is preferred using G2B as adhesive on air-abraded/polished dentin. Air polishing with BG positively influenced dentin bond strength for both application methods.


Subject(s)
Air Abrasion, Dental , Composite Resins , Dental Bonding , Dentin-Bonding Agents , Dentin , Materials Testing , Resin Cements , Surface Properties , Tensile Strength , Dental Bonding/methods , Humans , Composite Resins/chemistry , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dental Stress Analysis , Acid Etching, Dental/methods , Dental Polishing/methods , Stress, Mechanical , Dental Materials/chemistry , Powders
2.
Oper Dent ; 48(3): 294-303, 2023 May 01.
Article in English | MEDLINE | ID: mdl-36656317

ABSTRACT

This study aimed to compare the fracture toughness of molars with wide mesio-occlusal-distal (MOD) cavities restored with regular and flowable bulk-fill resin composite and a conventional resin composite after 250,000 mechanical cycles of chewing simulation. Thirty-two extracted mandibular third molars were selected and class II MOD cavities involving 2/3 of the intercuspal width and 4 mm depth were prepared. Teeth were divided into four groups based on resin composite type and insertion technique (n=8): (1) CT, unprepared teeth (control); (2) CV, conventional resin composite (Tetric N-Ceram, Ivoclar Vivadent) with incremental technique; (3) R-BF, regular bulk-fill resin composite (Tetric N-Ceram Bulk Fill, Ivoclar Vivadent) with a single increment; and (4) F-BF, flowable bulk-fill resin composite (Tetric N-Flow Bulk Fill, Ivoclar Vivadent) with a single increment, except for a 1-mm-thick layer at the occlusal surface, restored with conventional resin composite (Tetric N-Ceram). All specimens were evaluated to detect the presence and propagation of enamel cracks using a LED transilluminator before and after 250,000 mechanical cycles (SD Mechatronic GmbH). After a chewing simulation, they were subjected to a compressive force in a universal testing machine (DL-2000, EMIC) until fracture. The maximum fracture load of the specimens was measured (N) and the fracture patterns were classified based on the fracture site (above or below the cementoenamel junction [CEJ]). Data were statistically analyzed with one-way ANOVA. All specimens survived after 250,000 mechanical cycles, and no statistically significant differences among groups were observed regarding the fracture toughness (p<0.05). The fracture analysis demonstrated that failures below the CEJ were more common in CV (75%), while CT, R-BF, and F-BF showed this type of failure in 38%, 63%, and 63% of the specimens, respectively. The results of the crack analysis showed that the occurrence of new cracks and crack propagation was also higher in CV (33.3%), followed by R-BF, F-BF, and CT (14%, 14%, and 11% of the specimens, respectively). Teeth restored with regular and flowable bulk-fill composites showed similar fracture toughness after the chewing simulation compared to those restored with the conventional resin composite and unprepared teeth. Furthermore, teeth restored with both regular and flowable bulk-fill composites showed a lower incidence of enamel cracks and fractures below the CEJ compared to those restored with the conventional resin composite.


Subject(s)
Composite Resins , Mastication , Composite Resins/therapeutic use , Acrylic Resins , Polyurethanes , Molar , Materials Testing , Dental Restoration, Permanent/methods
3.
Oper Dent ; 47(2): 131-137, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35290465

ABSTRACT

This clinical case describes an esthetic rehabilitation of a young patient presenting with erosive tooth wear. The etiological factors for the erosion in this clinical case was excessive carbonated beverages and lemon water intake. The patient's main complaint was the yellowish aspect of her smile. The treatment procedure selected was direct resin composite veneers in the six maxillary anterior teeth. A three-year follow-up of the case is presented. The three-year follow-up showed a successful clinical performance of the treatment procedure after a finishing/polishing protocol.


Subject(s)
Dental Veneers , Tooth Erosion , Composite Resins/therapeutic use , Female , Follow-Up Studies , Humans , Tooth Erosion/etiology , Tooth Erosion/therapy
4.
Oper Dent ; 46(4): 419-427, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34624104

ABSTRACT

OBJECTIVES: To evaluate the influence of ferrule effect and mechanical fatigue aging on glass-fiber post push-out bond strength (PBS) to root-canal dentin at different root thirds of premolars. METHODS AND MATERIALS: Thirty-two sound maxillary premolar teeth were collected, and randomly assigned to two experimental groups (n=16): 'Remaining Dentin Ferrule' (RDF) = coronal crown cut 2.0 mm above the cementoenamel junction (CEJ); 'Without Dentin Ferrule' (WDF) = coronal crown cut at the cemento-enamel junction. Teeth were endodontically treated, post spaces were prepared up to 10.0-mm depth from CEJ, and glass-fiber posts were cemented using a dual-cure self-adhesive composite cement. Standardized cores were built using a light-cure composite, upon which tooth cores were prepared using a 1.5-mm taper ogival-end diamond bur. Crowns were handmade using self-cure acrylic resin and cemented using the aforementioned composite cement. Half of the specimens were subjected to 1,200,000 cycles of mechanical fatigue in a chewing simulator (F = 'Fatigue'), while the other half were stored in distilled water at 37°C for 1 week (C = 'Control'). All specimens were horizontally sectioned into 1.0-mm thick slices prior to PBS test; the failure modes were assessed using stereomicroscopy and scanning electron microscopy (SEM). Data were analyzed for each root third using two-way analysis of variance (ANOVA) followed by Tukey HSD post-hoc test; frequency distribution was compared by Chi-square test (α=0.05) and post-hoc comparisons with Bonferroni. RESULTS: The mean PBS in MPa (SD) were = RDF_F = 10.4 (2.9); WDF_F = 6.9 (1.7); RDF_C = 14.5 (2.7); WDF_C = 14.2 (2.9). Similar PBS were found for the root thirds. For all root thirds, significant differences were found for both the factors Dentin Ferrule and Fatigue, and their interaction (p<0.05). The lowest PBS was found for specimens without dentin ferrule subjected to chewing fatigue (p<0.001). Most failures occurred at the composite cement/dentin interface, followed by mixed and composite cement/glass-fiber post interfacial failures. There was a significant increase in mixed failures for the WDF_F group (p<0.001). CONCLUSION: Absence of 2.0-mm remaining dentin ferrule in premolars resulted in a higher decrease of the glass-fiber posts' PBS to dentin after mechanical fatigue, irrespective of root third.


Subject(s)
Post and Core Technique , Composite Resins , Crowns , Dental Materials , Dental Stress Analysis , Dentin , Glass , Mastication , Materials Testing , Resin Cements
5.
Oper Dent ; 46(1): 63-74, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33351938

ABSTRACT

CLINICAL RELEVANCE: The use of multipeak LED light-curing guarantees efficiency on light activation of Ivocerin-containing light-cured resin cement.


Subject(s)
Curing Lights, Dental , Resin Cements , Light-Curing of Dental Adhesives , Materials Testing
SELECTION OF CITATIONS
SEARCH DETAIL
...